{"product_id":"ashley-hearth-dvag17n-17-000-btu-direct-vent-natural-gas-wall-heater","title":"Ashley Hearth DVAG17N 17,000 BTU Direct Vent Natural Gas Wall Heater","description":"\u003cp\u003e570 square feet is a living room and the hallway it opens onto — the part of the house you actually occupy in the evening. That is what the DVAG17N is sized for. Its 17,000 BTU output carries an open main room without help from the furnace, which is what makes it a practical way to zone-heat the space you use and stop paying to warm the ones you don't.\u003c\/p\u003e\u003ch3\u003eSealed combustion, and why it matters at this size\u003c\/h3\u003e\u003cp\u003eA vent-free heater of comparable output dumps its combustion by-products and moisture into the room, which is why many jurisdictions restrict them and why they are a poor choice for a space you sit in all evening. This is a sealed direct vent appliance: outside air feeds the burner, exhaust leaves through the same wall penetration, and the two never mix with your indoor air. You get the heat without the humidity, the smell, or the code headache.\u003c\/p\u003e\u003ch3\u003eIt works when the power doesn't\u003c\/h3\u003e\u003cp\u003eThere is no cord on this heater. Output is set by a knob on top of the cabinet, and after the pilot is lit the internal thermostat maintains the setting without any electronics involved. Since natural gas keeps flowing when the grid goes down, a winter outage leaves you with a heater that simply carries on — which is a meaningful thing to own if you have ever sat through a multi-day one.\u003c\/p\u003e\u003ch3\u003eRunning on natural gas\u003c\/h3\u003e\u003cp\u003eNatural gas is the cheapest way to run this heater and the least hands-on: the supply is continuous, there is no tank to monitor, and nothing to refill in the middle of a cold week. The trade-off is that it has to reach the wall you are mounting to. If a line is already nearby — many homes have one for a range, dryer, or water heater — the run is usually short. If your property has no gas main at the street, the propane version of this model is the one you want.\u003c\/p\u003e\u003ch3\u003eSizing it right\u003c\/h3\u003e\u003cp\u003e570 square feet is the working number, and in a typical house that means an open living room plus whatever it connects to. If your main floor is broadly open, this is usually the model that carries it. If it is chopped into separate rooms, the heat will concentrate where the unit is mounted — worth planning the location around. Approved for mobile and modular homes in the USA and for conventional construction.\u003c\/p\u003e\u003ch3\u003eMoving the heat further\u003c\/h3\u003e\u003cp\u003eConvection alone will heat the room, but in an open plan the far end warms slowly. The matched \u003cstrong\u003eDVB17\u003c\/strong\u003e blower, sold separately, moves that air deliberately. It does need to be plugged in — the heater stays non-electric only for as long as you leave the blower off it.\u003c\/p\u003e\u003ch3\u003eSame heater, different fuel\u003c\/h3\u003e\u003cp\u003eNot on a natural gas line? The same cabinet is built in these configurations:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag17l-17-000-btu-direct-vent-propane-wall-heater\"\u003eDVAG17L — Liquid Propane\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag17-df-17-000-btu-direct-vent-dual-fuel-wall-heater\"\u003eDVAG17-DF — Dual Fuel\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 570 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVenting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectricity Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOff\/Pilot\/1\/2\/3\/4\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" - 10.5\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Manifold Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Clearances\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\"bottom, 6\"sides, 46\"top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Thickness Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5\"min - 10\"max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo- Sold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile Home Approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI STD Z21.86-2016 (R2021) CSA STD 2.32-2016 (R2021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstall Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e893237\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVietnam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDocumentation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2024\/01\/853277-DVAG-11_17_30-EN_FR-1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2019\/10\/852469-DV-Warranty.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWarranty Information (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e⚠️ California Prop 65 Warning\u003c\/h3\u003e\u003cp\u003eThis product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects, and\/or other reproductive harm. For more information, go to www.P65warnings.ca.gov\u003c\/p\u003e","brand":"Ashley Hearth","offers":[{"title":"Default Title","offer_id":50568715206895,"sku":"DVAG17N","price":549.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/9683\/2421\/files\/DVAG17N_Main-scaled.jpg?v=1787590220","url":"https:\/\/fyredirect.com\/products\/ashley-hearth-dvag17n-17-000-btu-direct-vent-natural-gas-wall-heater","provider":"Fyre Direct","version":"1.0","type":"link"}