{"product_id":"ashley-hearth-dvag17l-17-000-btu-direct-vent-propane-wall-heater","title":"Ashley Hearth DVAG17L 17,000 BTU Direct Vent Propane Wall Heater","description":"\u003cp\u003e570 square feet is a living room and the hallway it opens onto — the part of the house you actually occupy in the evening. That is what the DVAG17L is sized for. Its 17,000 BTU output carries an open main room without help from the furnace, which is what makes it a practical way to zone-heat the space you use and stop paying to warm the ones you don't.\u003c\/p\u003e\u003ch3\u003eSealed combustion, and why it matters at this size\u003c\/h3\u003e\u003cp\u003eA vent-free heater of comparable output dumps its combustion by-products and moisture into the room, which is why many jurisdictions restrict them and why they are a poor choice for a space you sit in all evening. This is a sealed direct vent appliance: outside air feeds the burner, exhaust leaves through the same wall penetration, and the two never mix with your indoor air. You get the heat without the humidity, the smell, or the code headache.\u003c\/p\u003e\u003ch3\u003eOff-grid by design\u003c\/h3\u003e\u003cp\u003eThe unit requires no electrical supply whatsoever. A top-mounted control knob sets the heat level and a mechanical thermostat holds it there. Paired with a propane tank, that makes the whole heating system independent of the utility grid — no wiring to run, no generator to start, nothing to fail in an outage. For a cabin, a camp, or a rural property at the end of a long service line, that independence is usually the whole point.\u003c\/p\u003e\u003ch3\u003eRunning on liquid propane\u003c\/h3\u003e\u003cp\u003ePropane is what makes this heater workable where there is no gas main — rural properties, cabins, hunting camps, detached shops. Ashley recommends a minimum 100 lb tank so you are not refilling constantly through the heating season; larger tanks stretch the interval further. Tank placement matters too: keep the run to the regulator short and the tank accessible for the delivery truck in winter.\u003c\/p\u003e\u003ch3\u003eSizing it right\u003c\/h3\u003e\u003cp\u003e570 square feet is the working number, and in a typical house that means an open living room plus whatever it connects to. If your main floor is broadly open, this is usually the model that carries it. If it is chopped into separate rooms, the heat will concentrate where the unit is mounted — worth planning the location around. Approved for mobile and modular homes in the USA and for conventional construction.\u003c\/p\u003e\u003ch3\u003eMoving the heat further\u003c\/h3\u003e\u003cp\u003eConvection alone will heat the room, but in an open plan the far end warms slowly. The matched \u003cstrong\u003eDVB17\u003c\/strong\u003e blower, sold separately, moves that air deliberately. It does need to be plugged in — the heater stays non-electric only for as long as you leave the blower off it.\u003c\/p\u003e\u003ch3\u003eSame heater, different fuel\u003c\/h3\u003e\u003cp\u003eIf your property has a gas main rather than a tank, the same heater is offered as:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag17n-17-000-btu-direct-vent-natural-gas-wall-heater\"\u003eDVAG17N — Natural Gas\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag17-df-17-000-btu-direct-vent-dual-fuel-wall-heater\"\u003eDVAG17-DF — Dual Fuel\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 570 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVenting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectricity Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOff\/Pilot\/1\/2\/3\/4\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\" - 14\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Manifold Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Clearances\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\"bottom, 6\"sides, 46\"top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Thickness Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5\"min - 10\"max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo- Sold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile Home Approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA STD 2.32-2016 (R2021) ANSI STD Z21.86-2016 (R2021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstall Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e893237 - Kit, Vent Tube (DVAG17)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVietnam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDocumentation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2024\/01\/853277-DVAG-11_17_30-EN_FR-1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2019\/10\/852469-DV-Warranty.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWarranty Information (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e⚠️ California Prop 65 Warning\u003c\/h3\u003e\u003cp\u003eThis product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects, and\/or other reproductive harm. For more information, go to www.P65warnings.ca.gov\u003c\/p\u003e","brand":"Ashley Hearth","offers":[{"title":"Default Title","offer_id":50568717795567,"sku":"DVAG17L","price":549.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/9683\/2421\/files\/DVAG17L_Main-scaled.jpg?v=1787590348","url":"https:\/\/fyredirect.com\/products\/ashley-hearth-dvag17l-17-000-btu-direct-vent-propane-wall-heater","provider":"Fyre Direct","version":"1.0","type":"link"}