{"product_id":"ashley-hearth-dvag17-df-17-000-btu-direct-vent-dual-fuel-wall-heater","title":"Ashley Hearth DVAG17-DF 17,000 BTU Direct Vent Dual Fuel Wall Heater","description":"\u003cp\u003e570 square feet is a living room and the hallway it opens onto — the part of the house you actually occupy in the evening. That is what the DVAG17-DF is sized for. Its 17,000 BTU output carries an open main room without help from the furnace, which is what makes it a practical way to zone-heat the space you use and stop paying to warm the ones you don't.\u003c\/p\u003e\u003ch3\u003eSealed combustion, and why it matters at this size\u003c\/h3\u003e\u003cp\u003eA vent-free heater of comparable output dumps its combustion by-products and moisture into the room, which is why many jurisdictions restrict them and why they are a poor choice for a space you sit in all evening. This is a sealed direct vent appliance: outside air feeds the burner, exhaust leaves through the same wall penetration, and the two never mix with your indoor air. You get the heat without the humidity, the smell, or the code headache.\u003c\/p\u003e\u003ch3\u003eIndependent of the grid, whichever fuel you run\u003c\/h3\u003e\u003cp\u003eWhether it is plumbed for natural gas or propane, this heater needs no electrical connection. Heat is dialed in with a knob on the cabinet top and held by a mechanical thermostat. Nothing stops working when the power does, so the appliance stays useful in exactly the conditions that make people wish they had bought one.\u003c\/p\u003e\u003ch3\u003eDual fuel: set it up for either supply\u003c\/h3\u003e\u003cp\u003eThis model can be configured to run on natural gas or liquid propane, which is worth more than it first sounds. If you are building, buying, or not yet sure what the property will have, you are not committing to a fuel at purchase. If you rent the place out or sell it later, the next occupant is not stuck with the wrong appliance. And if you are on propane now but a gas main is coming down the road, the heater does not become obsolete when it arrives.\u003c\/p\u003e\u003ch3\u003eSizing it right\u003c\/h3\u003e\u003cp\u003e570 square feet is the working number, and in a typical house that means an open living room plus whatever it connects to. If your main floor is broadly open, this is usually the model that carries it. If it is chopped into separate rooms, the heat will concentrate where the unit is mounted — worth planning the location around. Approved for mobile and modular homes in the USA and for conventional construction.\u003c\/p\u003e\u003ch3\u003eMoving the heat further\u003c\/h3\u003e\u003cp\u003eConvection alone will heat the room, but in an open plan the far end warms slowly. The matched \u003cstrong\u003eDVB17\u003c\/strong\u003e blower, sold separately, moves that air deliberately. It does need to be plugged in — the heater stays non-electric only for as long as you leave the blower off it.\u003c\/p\u003e\u003ch3\u003eSame heater, different fuel\u003c\/h3\u003e\u003cp\u003eIf your fuel supply is already settled, the single-fuel versions of this cabinet are:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag17n-17-000-btu-direct-vent-natural-gas-wall-heater\"\u003eDVAG17N — Natural Gas\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag17l-17-000-btu-direct-vent-propane-wall-heater\"\u003eDVAG17L — Liquid Propane\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 570 sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNatural Gas, Liquid Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVenting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectricity Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOff\/Pilot\/1\/2\/3\/4\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Thickness Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5\"min - 10\"max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo- Sold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile Home Approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI STD Z21.86-2016 (R2021) CSA STD 2.32-2016 (R2021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVietnam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDocumentation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2020\/08\/854081-DVAG11_17_25-Dual-Fuel.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2024\/07\/DVAG-DF-Warranty.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWarranty Information (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e⚠️ California Prop 65 Warning\u003c\/h3\u003e\u003cp\u003eThis product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects, and\/or other reproductive harm. For more information, go to www.P65warnings.ca.gov\u003c\/p\u003e","brand":"Ashley Hearth","offers":[{"title":"Default Title","offer_id":50568720285935,"sku":"DVAG17-DF","price":599.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/9683\/2421\/files\/Direct-Vent_Ashley_DVAG17-DF_Main-Image-jpg.webp?v=1787590385","url":"https:\/\/fyredirect.com\/products\/ashley-hearth-dvag17-df-17-000-btu-direct-vent-dual-fuel-wall-heater","provider":"Fyre Direct","version":"1.0","type":"link"}