{"product_id":"ashley-hearth-dvag11n-11-000-btu-direct-vent-natural-gas-wall-heater","title":"Ashley Hearth DVAG11N 11,000 BTU Direct Vent Natural Gas Wall Heater","description":"\u003cp\u003eThe DVAG11N covers the awkward middle ground: more room than a plug-in space heater can handle, not enough to justify extending your central system. Rated at 11,000 BTU for spaces up to 375 square feet, it suits a large bedroom, a converted garage, a sunroom, or an addition that the ductwork never reached. The cabinet is 17.36 inches wide and just 6.61 inches deep, so it sits close to the wall in rooms where floor space is already spoken for.\u003c\/p\u003e\u003ch3\u003eNo chimney, no flue, no rebuild\u003c\/h3\u003e\u003cp\u003eRetrofitting heat into a room the ductwork skipped usually means a masonry chimney or a Class A flue running up through the structure. This unit needs neither. The entire venting path is a single coaxial pipe punched through one exterior wall — intake and exhaust share the same penetration, which is why the wall only has to be between 4.5 and 10 inches thick and why the install is a morning's work rather than a project. The vent kit ships in the carton.\u003c\/p\u003e\u003ch3\u003eIt works when the power doesn't\u003c\/h3\u003e\u003cp\u003eThere is no cord on this heater. Output is set by a knob on top of the cabinet, and after the pilot is lit the internal thermostat maintains the setting without any electronics involved. Since natural gas keeps flowing when the grid goes down, a winter outage leaves you with a heater that simply carries on — which is a meaningful thing to own if you have ever sat through a multi-day one.\u003c\/p\u003e\u003ch3\u003eRunning on natural gas\u003c\/h3\u003e\u003cp\u003eNatural gas is the cheapest way to run this heater and the least hands-on: the supply is continuous, there is no tank to monitor, and nothing to refill in the middle of a cold week. The trade-off is that it has to reach the wall you are mounting to. If a line is already nearby — many homes have one for a range, dryer, or water heater — the run is usually short. If your property has no gas main at the street, the propane version of this model is the one you want.\u003c\/p\u003e\u003ch3\u003eSizing it right\u003c\/h3\u003e\u003cp\u003eThe 375 square foot rating suits a large bedroom, a converted garage, a sunroom, or an addition that never got ducted. Two exterior walls, poor insulation, or a vaulted ceiling will each pull the practical figure down, so size with a margin if any of those apply to your space. Cleared for use in mobile and modular homes in the USA as well as standard construction.\u003c\/p\u003e\u003ch3\u003eMoving the heat further\u003c\/h3\u003e\u003cp\u003eLeft alone, the heater moves its warmth by natural convection. In a longer room you may want it pushed further, and the optional \u003cstrong\u003eDVB11\u003c\/strong\u003e blower is made for this cabinet (sold separately). Worth knowing: the blower runs on electricity, so fitting one gives up the outage-proof quality described above.\u003c\/p\u003e\u003ch3\u003eSame heater, different fuel\u003c\/h3\u003e\u003cp\u003eNot on a natural gas line? The same cabinet is built in these configurations:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag11l-11-000-btu-direct-vent-propane-wall-heater\"\u003eDVAG11L — Liquid Propane\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag11-df-11-000-btu-direct-vent-dual-fuel-wall-heater\"\u003eDVAG11-DF — Dual Fuel\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 375 Sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNatural Gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVenting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectricity Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOff\/Pilot\/1\/2\/3\/4\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\" - 10.5\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Manifold Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Clearances\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\"bottom, 6\"sides, 46\"top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Thickness Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5\"min - 10\"max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo- Sold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile Home Approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI STD Z21.86-2016 (R2021) CSA STD 2.32-2016 (R2021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstall Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e893236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVietnam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDocumentation\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2024\/07\/853277-DVAG-11_17_30-EN_FR.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003e⚠️ California Prop 65 Warning\u003c\/h3\u003e\u003cp\u003eThis product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects, and\/or other reproductive harm. For more information, go to www.P65warnings.ca.gov\u003c\/p\u003e","brand":"Ashley Hearth","offers":[{"title":"Default Title","offer_id":50568723464431,"sku":"DVAG11N","price":449.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/9683\/2421\/files\/DVAG11N_Front-scaled.jpg?v=1787590433","url":"https:\/\/fyredirect.com\/products\/ashley-hearth-dvag11n-11-000-btu-direct-vent-natural-gas-wall-heater","provider":"Fyre Direct","version":"1.0","type":"link"}