{"product_id":"ashley-hearth-dvag11l-11-000-btu-direct-vent-propane-wall-heater","title":"Ashley Hearth DVAG11L 11,000 BTU Direct Vent Propane Wall Heater","description":"\u003cp\u003eThe DVAG11L covers the awkward middle ground: more room than a plug-in space heater can handle, not enough to justify extending your central system. Rated at 11,000 BTU for spaces up to 375 square feet, it suits a large bedroom, a converted garage, a sunroom, or an addition that the ductwork never reached. The cabinet is 17.36 inches wide and just 6.61 inches deep, so it sits close to the wall in rooms where floor space is already spoken for.\u003c\/p\u003e\u003ch3\u003eNo chimney, no flue, no rebuild\u003c\/h3\u003e\u003cp\u003eRetrofitting heat into a room the ductwork skipped usually means a masonry chimney or a Class A flue running up through the structure. This unit needs neither. The entire venting path is a single coaxial pipe punched through one exterior wall — intake and exhaust share the same penetration, which is why the wall only has to be between 4.5 and 10 inches thick and why the install is a morning's work rather than a project. The vent kit ships in the carton.\u003c\/p\u003e\u003ch3\u003eOff-grid by design\u003c\/h3\u003e\u003cp\u003eThe unit requires no electrical supply whatsoever. A top-mounted control knob sets the heat level and a mechanical thermostat holds it there. Paired with a propane tank, that makes the whole heating system independent of the utility grid — no wiring to run, no generator to start, nothing to fail in an outage. For a cabin, a camp, or a rural property at the end of a long service line, that independence is usually the whole point.\u003c\/p\u003e\u003ch3\u003eRunning on liquid propane\u003c\/h3\u003e\u003cp\u003ePropane is what makes this heater workable where there is no gas main — rural properties, cabins, hunting camps, detached shops. Ashley recommends a minimum 100 lb tank so you are not refilling constantly through the heating season; larger tanks stretch the interval further. Tank placement matters too: keep the run to the regulator short and the tank accessible for the delivery truck in winter.\u003c\/p\u003e\u003ch3\u003eSizing it right\u003c\/h3\u003e\u003cp\u003eThe 375 square foot rating suits a large bedroom, a converted garage, a sunroom, or an addition that never got ducted. Two exterior walls, poor insulation, or a vaulted ceiling will each pull the practical figure down, so size with a margin if any of those apply to your space. Cleared for use in mobile and modular homes in the USA as well as standard construction.\u003c\/p\u003e\u003ch3\u003eMoving the heat further\u003c\/h3\u003e\u003cp\u003eLeft alone, the heater moves its warmth by natural convection. In a longer room you may want it pushed further, and the optional \u003cstrong\u003eDVB11\u003c\/strong\u003e blower is made for this cabinet (sold separately). Worth knowing: the blower runs on electricity, so fitting one gives up the outage-proof quality described above.\u003c\/p\u003e\u003ch3\u003eSame heater, different fuel\u003c\/h3\u003e\u003cp\u003eIf your property has a gas main rather than a tank, the same heater is offered as:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag11n-11-000-btu-direct-vent-natural-gas-wall-heater\"\u003eDVAG11N — Natural Gas\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ashley-hearth-dvag11-df-11-000-btu-direct-vent-dual-fuel-wall-heater\"\u003eDVAG11-DF — Dual Fuel\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 375 Sq ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLiquid Propane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVenting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWall Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectricity Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Settings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOff\/Pilot\/1\/2\/3\/4\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11\" - 14\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Manifold Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\" W.C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Clearances\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\"bottom, 6\"sides, 46\"top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWall Thickness Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5\"min - 10\"max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth (in)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight (lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBlower Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo- Sold Separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Included\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobile Home Approved\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eANSI STD Z21.86-2016 (R2021) CSA STD 2.32-2016 (R2021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstall Kit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e893236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterials\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVietnam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eDocumentation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2024\/01\/853277-DVAG-11_17_30-EN_FR-1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOwner's Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.usstove.com\/wp-content\/uploads\/2019\/10\/852469-DV-Warranty.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWarranty Information (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e⚠️ California Prop 65 Warning\u003c\/h3\u003e\u003cp\u003eThis product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer, birth defects, and\/or other reproductive harm. For more information, go to www.P65warnings.ca.gov\u003c\/p\u003e","brand":"Ashley Hearth","offers":[{"title":"Default Title","offer_id":50568726511855,"sku":"DVAG11L","price":449.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0533\/9683\/2421\/files\/DVAG11L-Main-scaled.jpg?v=1787590457","url":"https:\/\/fyredirect.com\/products\/ashley-hearth-dvag11l-11-000-btu-direct-vent-propane-wall-heater","provider":"Fyre Direct","version":"1.0","type":"link"}